Skip to content
Microsystems, Electronics and Acoustics
ISSN 2523-4447 · e‑ISSN 2523-4455 Open Access · CC BY-SA 4.0
Vol. 22 · Issue 6 · 2017 Dec 29, 2017 Vacuum, plasma and quantum electronics

Improvement of parameters X-ray television systems on the basis of electronic converters

NS
Natalia Victorovna Shinkarenko Corresponding National Technical University of Ukraine “Igor Sikorsky Kyiv Polytechnic Institute” Ukraine
Pages18-28 PublishedDec 29, 2017
VOL 22 · ISS 6 · 2017 View issue

Abstract

Flat Panel Detectors (FPD) emerge as a next-generation digital x-ray technology. The numerous advantages of flat panel detectors over x-ray film, computed radiography image plates, and image-intensifier tubes are given. They include time efficiency through bypassing chemical processing and the ability to digitally transfer and enhance images. The most important parameters of different technologies are discussed. The comparison table of modern FPD is presented. Emergence and distribution of industrial television, creation of different types of vacuum transfer tubes, in particular for x-ray range, and then and their solid-state analogs promoted use and development the x-ray TV systems of methods of researches. In comparison with radiographic these methods have essential advantages and open essentially new opportunities of researches. With creation and mass introduction of modern computer facilities, in particular her attraction to processes of registration, visualization and processing of shadow x-ray images of objects. Now the special branch is put by x-ray TV systems of pulse action that are widely used in medicine, defectoscopy, military science and different technological processes. Thanks to a number of essential positive qualities (the small weight and dimensions, simplicity of a design, an opportunity of both the panoramic, and directed raying, the low power consumption and also an opportunity to control dynamic objects and processes) devices have received the greatest use in technology of nondestructive control of materials in non-stationary conditions. The device and the scheme of operation of the x-ray electron-optical converter with an axial arrangement of the receiver is considered. As the converter light signal matrixes on the basis of charge-coupled devices, and also CMOS sensors are used. Transformation of x-ray radiation to the image, available to the operator, takes place several stages. At each step of transformations primary information is distorted that leads to deterioration in the visual image. Key parameters of x-ray electron-optical converter are specified, shortcomings of this type of technologies are noted. By means of digital the x-ray TV systems of systems it is possible to receive images which quality is much higher qualities of x-ray films and computer radiography. As a result of the big relation signal/noise for digital detector system possible indication of defects, is less than the size of pixel. The sizes of solid-state detectors several times smaller for x-ray electron-optical converter. Besides they have no geometrical distortions and reflections. Other advantage of flat detectors is much faster processing of results at rather high quality of the image which gives a gain in time. The digital X-ray analysis allows to reduce a dose of x-ray radiation due to installation of an exposition at which the necessary noise level is supported. The development and improvement of technologies and technical means in the x-ray non-destructive control has taken the way of using highly stable sources of radiation, modern radiation converters, computer methods of their management, application of the newest methods of digital image processing and their analysis. There is an active transition of control systems with the use of radiation x-ray electron-optical converter to systems using multi-element transducers manufactured by microelectronics: amorphous selenium and amorphous silicon. The use of a television channel in such systems greatly expands the functionality of the equipment. Ref. 36, fig. 4, tabl. 3

Keywords

References

  1. V. V. Kljuev, F. R. Sosnin, and A. V. Kovalev, Nerazrushajushhij kontrol’ i diagnostika: spravochnik [Non-destructive testing and diagnos-tics: reference book] . Moskow, Russia: Mashynostroenie, 2005. ISBN: 5-217-03300-2
  2. V. V. Kljuev and F. R. Sosnin, Teorija i praktika radiacionnogo kontrolja. [Theory and practice of radiation monitoring] . Moskow, Russia: Mashinostroenie, 1998.
  3. M. B. Lebedev, V. A. Sidulenko, and V. A. Udot, “Analiz sovremennogo sostojanija i razvitija sistem cifrovoj rentgenografi [Analysis of the current state and development of digital radiography systems],” Bull. Tomsk Polytech. Univ. , vol. 312, no. 2, pp. 47–55, 2008. URL: http://izvestiya.tpu.ru/ru/archive/old/article.html?id=187641&journalId=176237
  4. I. B. Belova and V. M. Kitaev, “Cifrovye tehnologi poluchenija rentgenovskogo izobrazhenija: princip formirovanija i tipy (obzor literatury) [Digital technology for X-ray imaging: the principle of formation and types (literature review)],” Med. vizualizacija , no. 1, pp. 30–40, 2000.
  5. O. A. Sidulenko, “Sovremennoe sostojanie i napravlenija sovershenstvovanija tehnologij radiacionnogo kontrolja [Current state condition and improvement directions of X-Ray inspection technologies],” Expo. Oil Gas , no. 3 (28), pp. 14–16, 2013. URL: http://runeft.ru/en/articles/39/55382.htm
  6. A. A. Maiorov, “Cifrovye tehnologii v radiacionnom kontrole. [Digital technologies in radiation monitoring],” V MIRE Nerazrus. KONTROLYA (V MIRE NK) , no. 3 (45), pp. 5–12, 2009. URL: http://www.ndtworld.com/catalog.html?itemid=115&choice=1
  7. S. V. Denbnoveckij and O. V. Leshhishin, Elektronnі sistemi. Navchalnyi posibnyk. [Electronic systems. Schoolbook.] . Kyiv, Ukraine: NTUU ”KPІ”, 2011. ISBN: 978-966-622-418-0
  8. A. I. Mazurov, “Poslednie dostizhenija v cifrovoj rentgenotehnike” [“Recent advances in digital X-ray technology],” Med. Teh. , no. 5, pp. 10–14, 2010.
  9. D. Bernard and K. Brajnt, “Ispol’zovanie poslednih tehnologicheskih dostizhenij dlja rentgenovskogo kontrolja jelektronnyh izdelij [Use of the latest technological advances for X-ray inspection of electronic products],” Technol. Electron. Ind. , no. 2, pp. 16–21, 2012. URL: http://www.tech-e.ru/2012_2_34.php
  10. S. Gaft, “Rentgenovskij kontrol’ – moshhnoe sredstvo dlja diag-nostiki i lokalizacii defektov sovremennyh pechatnih uzlov [X-ray inspection is a powerful tool for diagnosing and localizing defects in modern printing units],” Kompon. i Tehnol. , no. 7, 2004. URL: www.kit-e.ru/articles/circuitbrd/2004_07_182.php
  11. V. V. Kljuev, “Sovremennye sredstva i metody cifrovoj radiac-ionnoj defektoskopii [Modern means and methods of digital radiation defectoscopy],” V MIRE Nerazrus. KONTROLYA (V MIRE NK) , no. 4, pp. 52–56, 2002.
  12. M. Shmakov, “Vybor sistemy rentgenovskogo kontrolja. Vzgljad tehnologa [Selecting the X-ray inspection system],” Technol. Electron. Ind. , no. 4, pp. 60–68, 2006. URL: http://www.tech-e.ru/2006_4_60.php
  13. I. I. Cukkerman, “Puti povyshenija informacionnoj emkosti v televidenii [Ways to improve information capacity in television],” Usp. nauchnoj Fotogr. , no. XXIII, pp. 58–62, 1985.
  14. L. Y. Mogilner and E. N. Markina, “Opyt primenenija tehnologii cifrovoj radiografii v praktike stroitel’stva i jekspluatacii trubo-provodov “[Experience of radiography digital technology in practice of construction and operation of pipelines],” V MIRE Nerazrus. KONTROLYA (V MIRE NK) , no. 2, pp. 42–46, 2009. URL: http://www.ndtworld.com/catalog.html?itemid=114&choice=8
  15. V. A. Troickij, “Perspektivy razvitija radiacionnogo kontrolja svarnyh soedinenij [Perspective for the development of radiation monitoring of welded joints],” Qual. Control Tools Tech. , no. 1 (34), pp. 5–13, 2015. URL: http://mpky.nung.edu.ua/uk/content/%E2%84%9634-2015
  16. V. A. Troitskii, S. R. Mikhailov, R. A. Pastovenskii, and D. S. Shilo, “Sovremennye sistemy radiacionnogo nerazrushajushhego kontrolja [Modern systems of radiation nondestructive inspection],” Tekhnicheskaya Diagnostika i Nerazrus. Kontrol , no. 1, pp. 23–35, Jan. 2015. DOI: 10.15407/tdnk2015.01.03
  17. D. N. Nikolaev, “Jelektronno-opticheskie preobrazovateli. Istorija razvitija i vidy pokolenij [Electron-optical converters. History of development and types of generations],” Proc. Tomsk State Univ. Control Syst. Radioelectron. , no. 1, pp. 29–33, 2007. URL: https://journal.tusur.ru/en/archive/1-2007/electron-optical-converters-history-of-development-and-kinds-of-generations
  18. “Filin 16N2048M.” [Online]. Available: http://www.tehastor.ru/index.php?page=filin . [Accessed: 10-Sep-2017].
  19. “Siemens HIDEQ 33-4 ISX (13») datasheet.” Siemens. URL: http://w9.siemens.com/cms/oemproducts/Home/Products/Documents/ds_HIDEQ_33-4_ISX_eng_2012-02.pdf
  20. A. Litvinov, “Vysokoe kachestvo izobrazhenija. Poslednee pokolenie detektorov rentgenovskogo izluchenija ‘SID-A50’ [High quality of image. The latest generation of X-ray detectors ‘SID-A50’],” Technol. Electron. Ind. , no. 6, pp. 44–47, 2011. URL: http://www.tech-e.ru/2011_6_44.php
  21. “Flat panel sensor C7942CA-22 | Hamamatsu Photonics.” [Online]. Available: http://www.hamamatsu.com/us/en/community/xndt/product/search/C7942CA-22/index.html . [Accessed: 10-Jun-2017].
  22. A. A. Borisov, J. A. Vejp, A. I. Mazurov, and M. B. Jelinson, “O dvuh tehnologijah postroenija cifrovyh priemnikov rentgenovskih izo-brazhenij [About two technologies for building digital x-ray re-ceivers]”,” Med. Teh. , no. 5, pp. 7–10, 2006.
  23. M. S. Grigorov, A. A. Nevrov, and O. O. Basov, “Raspoznavanie kontaktnyh ploshhadok kristallov integral’nyh mіkroshem na rentgenovskih izobrazhenijah [Recognition of contact areas of crystals of integrated microcircuits on X-ray images],” Inf. Syst. Technol. , no. 1, pp. 59–65, 2015.
  24. M. Wronski, “Development of a Flat Panel Detector with Avalanche Gain for Interventional Radiology,” University of Toronto, 2009. URL: https://tspace.library.utoronto.ca/handle/1807/19249
  25. “Excellence in X-ray Detection. Advanced X-ray Cameras for Scientific and Industrial Applications.” Princeton Instruments, p. 76, 2010. URL: http://www.princetoninstruments.com.cn/userfiles/files/assetLibrary/Catalogs/Princeton_Instruments-X-ray-camera-brochure_Final_B0_web.pdf
  26. M. Farrier, T. Achterkirchen, G. Wecksler, and A. Mrozack, “Shirokoformatnye KMOP-sensory s aktivnymi pikselami dlja cifrovoj rentgenografii [Very Large area CMOS active-pixel sensor for digital radiography],” Photonics , no. 2, pp. 88–99, 2013. URL: http://www.photonics.su/journal/article/3655
  27. M. S. Grigorov, “Classification of Digital Systems of Non-Destructive X-Ray Control of Microelectronic Products,” SPIIRAS Proc. , vol. 4, no. 35, p. 94, 2014. DOI: 10.15622/sp.35.7
  28. N. N. Blinov and E. Al., “Issledovanie parametrov skanirujushhih rentgenovskih system [Investigation of the parameters of scanning X-ray systems],” Med. Teh. , no. 5, pp. 8–11, 2004.
  29. V. A. Udod, V. A. Klimenov, A. I. Buller, E. J. Usachev, and A. K. Temnik, “Optimizacija osnovnyh parametrov mnogokanal’nyh ckanirujushhih sistem cifrovoj radiografii [Optimization of the main parameters of multichannel scanning systems of digital radiography],” Izv. Vyss. uchebnyh Zaved. Fiz. , vol. 56, no. 1–2, pp. 254–257, 2013. URL: https://elibrary.ru/item.asp?id=21635406
  30. “Rentgenotelevizionnyie sistemyi [X-ray television systems].” [Online]. Available: http://www.unitest-roentgen.ru/produktsiya/rentgenotelevizionnye-sistemy-kontrast/213-rentgenotelevizionnye-sistemy-kontrast-pd-s-ploskopanelnymi-detektorami . [Accessed: 10-Jun-2017].
  31. D. Bernard, “Kriterii vybora rentgenovskoj trubki [X-ray tube selection criteria],” Technol. Electron. Ind. , no. 4, pp. 38–43, 2010. URL: http://tech-e.ru/2010_4_38.php
  32. G. A. Mesjac, Impul’snaja jenergetika i jelektronika [Impulse energy and electronics] . Moskow, Rusiia: Nauka, 2004. ISBN: 5-02-033049-3
  33. S. P. Vavilov and V. I. Gorbunov, Impul’snoe rentgenovskoe izluchenie v defektoskopii [Pulsed x-ray radiation in defectoscopy] . Moskow, USSR: Energoatomizdat, 1985.
  34. A. I. Pushkarev, J. I. Isakova, R. V. Sazanov, and G. E. Holodnaja, Generacija puchkov zarjazhennyh chastic v diodah so vzryvo-jemissionnym katodom [Generation of charged particle beams in diodes with explosive emission cathode] . Moskow, Russia: Fiz-matlit, 2013. ISBN: 978-5-9221-1411-0
  35. N. G. Belii, V. N. Bukhenskii, S. R. Mikhailov, N. V. Slobodjan, and D. S. Shilo, “Otnositel’naja chuvstvitel’nost’ rentgenotelevizionnyh sistem na osnove impul’snyh rentgenovskih apparatov [Relative sensitivity of X-ray television systems based on pulsed X-ray units],” Tekhnicheskaya Diagnostika i Nerazrus. Kontrol , no. 1, pp. 39–44, 2013. URL: https://patonpublishinghouse.com/rus/journals/tdnk/2013/01/06
  36. N. G. Bely, S. V. Denbnovetskii, A. V. Leshchishin, S. R. Mikhailov, N. V. Slobodyan, and V. A. Troitskii, “Otnositel’naja chuvstvitel’nost’ rentgenotele-vizionnyh sistem na osnove vysokochuvsvitel’nyh PZS-kamer i rent-genovskih monokristallicheskih jekranov [Relative sensitivity of X-ray television systems based on high-sensitivity CCD cameras and X-ray single-crystal screens ],” Tekhnicheskaya Diagnostika i Nerazrus. Kontrol , no. 2, pp. 34–40, 2007.
§ 06 — Related

Similar articles in this journal

Related peer-reviewed studies published in this journal.
View all issues

Quasistatic Identification of The Shading Structure of Solar Panels by The Method of Cardinal Number Vectors

PhD, Assoc. Prof. Olena Olehivna Abakumova, Dr.Sc.(Eng.), Prof. Valerii Yakovych Zhuikov, Mykola O. Lukianov

In the article the problem of identification the shading structure of solar panels is considered. The relevance of the study is conditioned by the necessity of rapid and…

#solar panels #photovoltaic surface #shadow structure modeling #quasistatic identification
p. 362283.1-362283.7
10.20535/2523-4455.mea.362283

Similar Articles

You may also start an advanced similarity search for this article.